
Ireland’s Plumbing & Heating Magazine Awards
Exi-tite was delighted to pick up two prestigious prizes at Ireland’s Plumbing & Heating Magazine Awards in Belfast. Hundreds of guests at the Europa Hotel

Exi-tite was delighted to pick up two prestigious prizes at Ireland’s Plumbing & Heating Magazine Awards in Belfast. Hundreds of guests at the Europa Hotel

We were delighted to welcome the Marie Curie Clogher Valley team to Exi-tite Ballygawley to receive a £1,000 donation raised by our staff. This fantastic

As part of an ongoing commitment to strengthening its team and supporting continued business growth, leading HVAC supplier Exi-tite has appointed Trevor Girvan as Technical

Energy recovery now sits at the centre of HTM compliant air handling units. Andrew Robinson, Managing Director of Exi-tite Group, outlines how a strong understanding

We are pleased to share that Exi-tite Scotland is now sponsoring Mill United FC, supporting local grassroots football in the community. Mill United has been

Scott Johnston has been promoted to product manager for LG in Scotland, following a highly successful first year with the business. Commenting on the promotion,

Heat pump integration at Canalside, Woking
Project background
Exi-tite designed and supplied a renewable and robust heating solution for a mixed-use housing project in Woking, Surrey. Kane Group delivered the overall M&E package for the Canalside Purple Phase regeneration on behalf of main contractor Gilbert-Ash. The 14-month contract involved full M&E fit out of 82 flats and 10 three-storey townhouses in the medium-rise development, including a low-carbon, reliable and future-proof heating and hot water system.
System design
The system comprises 10×LG Therma V R32 Monobloc 9kW air-to-water heat pumps for the townhouses, each paired with a 250-litre World Heat pre-plumbed cylinder with integral buffer vessel.
LG’s compact, side-discharge units eliminate the need for refrigerant pipework and therefore simplify installation. Operating range spans -25°C to +35°C ambient, with water leaving temperatures up to 65°C. Performance is maintained at 100% output even at -7°C ambient and 55°C LWT, and the units deliver a COP of up to 4.18 at 7°C ambient/35°C LWT.
Key design features include:
• Inverter-driven R1 compressor (10-150Hz)
• Black Fin epoxy-coated heat exchanger coils for corrosion resistance
• Integrated hydronic module (pump, expansion vessel, plate heat exchanger)
• Low noise operation (50 dB(A) at 1metre).
This configuration provides efficient, decentralised heating across the installation, with individual plant for each residence.
The World Heat V-Cyl pre-plumbed heat pump cylinders are manufactured in the UK from duplex stainless steel and supplied with a 25-year vessel warranty.
Integrated components include:
• 50-litre buffer vessel
• Grundfos UPM3 circulation pump
• Honeywell 2-port and 3-port valves
• LG RS3 controller interface
In terms of performance, the cylinders offer 35-45-minute reheat times, 90-watt standing heat loss and ERP “B” rated insulation. The pre-plumbed design reduced installation time and coordination risks, ensuring consistency across all 10 apartments.
Carport challenge
Due to site constraints, the outdoor units were positioned within car ports. These semi-enclosed environments presented potential risks of restricted airflow and hot air recirculation, both of which could impair efficiency and long-term reliability.
To validate the installation, LG Electronics performed Computational Fluid Dynamics (CFD) modelling in ANSYS R19.2. Under boundary conditions of 35°C ambient and 100% load, results showed a maximum inlet air temperature of 38.5°C, well below the continuous operation threshold of 48°C. Discharge air left the car ports cleanly without recirculation into unit inlets. The conclusion was that the units would operate within safe thermal limits, confirming suitability of the constrained location.
Outcome
The completed installation of LG Therma V Monobloc ASHPs paired with World Heat pre-plumbed cylinders has delivered a robust, validated, low-carbon heating solution at the Canalside development.
Key benefits of the system include:
• Assured performance validated through CFD analysis for semi-enclosed car port installation
• Reduced installation time through factory-prepared, pre-plumbed hot water cylinders,
• A future-proof heating system combining renewable efficiency, corrosion-resistant construction and long warranties
This project also underlines how close collaboration between Ex-tite, Kane Group, LG Electronics and World Heat enabled the successful delivery of a sustainable and technically assured renewable heating solution.

Exi-tite is delighted to announce a new partnership with pioneering heat pump manufacturer Qvantum UK.

Exi-tite Scotland has thrown its support behind grassroots sport by sponsoring junior football team Hillwood Thistle for the upcoming season. Our branding will proudly feature

To celebrate International Women in Engineering Day on 23 June, we talk to Exi-tite Applications Engineer Mariane Galpo Doyle about her career in the HVAC
We deliver CPDs across the UK and Ireland to consultants, architects and M&E specialists.
Our presentations cover industry trends, technological innovations, and applications across a range of HVAC sectors.
15a Grange Road
Ballygawley
Dungannon
BT70 2LP
+44 (0) 28 855 67674
Mon-Thurs: 9am- 4pm
Fri: 8am-1pm
Unit 6 Dargan Court
Dargan Cresent
Belfast
BT3 9JP
+44 (0) 28 9077 7093
Mon-Thurs: 9am- 4pm
Fri: 8am-1pm
Unit A4
Queenslie Industrial Estate
Block 14
Glasgow
G33 4DR
+44 (0) 141 530 3511
Mon-Thurs: 9am- 4pm
Fri: 8am-3pm
Cannery Road
Carlow
Co. Carlow
R93 R2X7
+353 59 918 9859
Mon-Thurs: 9am- 4pm
Fri: 8am-1pm
Unit 6 Dargan Court
Dargan Cresent
Belfast
BT3 9JP
+44 (0) 28 9077 7093
Mon-Thurs: 9am- 4pm
Fri: 8am-1pm